Line Commands
4-15
4
Related Commands
silent-time (4-15)
timeout login response (4-13)
silent-time
This command sets the amount of time the management console is inaccessible
after the number of unsuccessful logon attempts exceeds the threshold set by the
password-thresh command. Use the no form to remove the silent time value.
Syntax
silent-time [seconds]
no silent-time
seconds - The number of seconds to disable console response.
(Range: 0-65535; 0: no silent-time)
Default Setting
The default value is no silent-time.
Command Mode
Line Configuration
Example
To set the silent time to 60 seconds, enter this command:
Related Commands
Related Commands (4-14)
databits
This command sets the number of data bits per character that are interpreted and
generated by the console port. Use the no form to restore the default value.
Syntax
databits {7 | 8}
no databits
7 - Seven data bits per character.
8 - Eight data bits per character.
Default Setting
8 data bits per character
Command Mode
Line Configuration
Console(config-line)#silent-time 60