C
OMMAND
L
INE
I
NTERFACE
4-74
Default Setting
None
Command Mode
Global Configuration
Command Usage
This command sets the local time zone relative to the Coordinated
Universal Time (UTC, formerly Greenwich Mean Time or GMT),
based on the earth’s prime meridian, zero degrees longitude. To display
a time corresponding to your local time, you must indicate the number
of hours and minutes your time zone is east (before) or west (after) of
UTC.
Example
Related Commands
show sntp (4-73)
calendar set
This command sets the system clock. It may be used if there is no time
server on your network, or if you have not configured the switch to receive
signals from a time server.
Syntax
calendar set hour min sec {day month year | month day year}
hour - Hour in 24-hour format. (Range: 0 - 23)
min - Minute. (Range: 0 - 59)
sec - Second. (Range: 0 - 59)
day - Day of month. (Range: 1 - 31)
month - january | february | march | april | may | june | july |
august | september | october | november | december
year - Year (4-digit). (Range: 2001 - 2101)
Console(config)#clock timezone Japan hours 8 minute 0 after-UTC
Console(config)#