Start IP Address – A single IP address, or the starting address of a
range.
End IP Address – The end address of a range.
Web – Click Security, IP Filter. Enter the IP addresses or range of
addresses that are allowed management access to an interface, and click
Add IP Filtering Entry.
Figure 3-40 IP Filter
CLI – This example restricts management access for Telnet clients.
Console(config)#management telnet-client 192.168.1.19 4-37
Console(config)#management telnet-client 192.168.1.25 192.168.1.30
Console(config)#exit
Console#show management all-client 4-38
Management IP Filter
HTTP-Client:
Start IP address End IP address
-----------------------------------------------
SNMP-Client:
Start IP address End IP address
-----------------------------------------------
TELNET-Client:
Start IP address End IP address
-----------------------------------------------
1. 192.168.1.19 192.168.1.19
2. 192.168.1.25 192.168.1.30
Console