SMC Networks SMCRPU14 Manual de usuario Pagina 21

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 38
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 20
2-1
CHAPTER 2:
INSTALLING THE
REDUNDANT POWER UNIT
Installation
The RPU may be placed on a desktop or mounted in a rack.
Caution: DO NOT place the RPU on the floor as the case is not
waterproof. It is recommended that this RPU be installed in
a network equipment rack.
Selecting a Site
RPU units can be mounted in a standard 19-inch equipment rack or on a
flat surface. Be sure to follow the guidelines below when choosing a
location.
•The site should:
- be at the center of all the devices you want to link and near a
power outlet.
- be able to maintain its temperature within 0 to 45 °C (32 to
110 °F) and its humidity within 5% to 95%, non-condensing
- provide adequate space (approximately two inches) on all sides for
proper air flow
- be accessible for installing, cabling and maintaining the devices
- allow the status LEDs to be clearly visible
Vista de pagina 20
1 2 ... 16 17 18 19 20 21 22 23 24 25 26 ... 37 38

Comentarios a estos manuales

Sin comentarios