SMC Networks Switch SMC8848M Manual de usuario Pagina 1

Busca en linea o descarga Manual de usuario para Los conmutadores de red SMC Networks Switch SMC8848M. SMC Networks Switch SMC8848M User's Manual Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 96
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 0
TigerStack II
10/100/1000
Gigabit Ethernet Switch
24/48 auto-MDI/MDI-X 10/100/1000BASE-T ports
4 RJ-45 ports shared with 4 SFP transceiver slots
2 10GBASE extender module slots
Non-blocking switching architecture
Support for a redundant power unit
Spanning Tree Protocol, RSTP, and MSTP
Up to 32 LACP or static 8-port trunks
Layer 2/3/4 CoS support through eight priority queues
Layer 3/4 traffic priority with IP Precedence and IP DSCP
Full support for VLANs with GVRP
IGMP multicast filtering and snooping
Manageable via console, Web, SNMP/RMON
Security features: ACL, RADIUS, 802.1x
Supports IPv4/IPv6, dual protocol stack
Installation Guide
SMC8824M
SMC8848M
Vista de pagina 0
1 2 3 4 5 6 ... 95 96

Indice de contenidos

Pagina 1 - 10/100/1000

TigerStack II10/100/1000Gigabit Ethernet Switch◆ 24/48 auto-MDI/MDI-X 10/100/1000BASE-T ports◆ 4 RJ-45 ports shared with 4 SFP transceiver slots◆ 2 10

Pagina 2

COMPLIANCESvi• This unit operates under SELV (Safety Extra Low Voltage) conditions according to IEC 60950. The conditions are only maintained if the e

Pagina 3 - Installation Guide

COMPLIANCESviiVeuillez lire à fond l'information de la sécurité suivante avant d'installer le Switch:AVERTISSEMENT: L’installation et la dép

Pagina 4 - Trademarks:

COMPLIANCESviiiBitte unbedingt vor dem Einbauen des Switches die folgenden Sicherheitsanweisungen durchlesen:WARNUNG: Die Installation und der Ausbau

Pagina 5

COMPLIANCESixWarnings and Cautionary MessagesWarnings (in German)Environmental StatementThe manufacturer of this product endeavours to sustain an envi

Pagina 6

COMPLIANCESxEnd of Product Life SpanThis product is manufactured in such a way as to allow for the recovery and disposal of all included electrical co

Pagina 7 - COMPLIANCES

xiTABLE OF CONTENTS1 About the TigerStack II 10/100/1000 . . . . . . . . . . . . . 1-1Overview . . . . . . . . . . . . . . . . . . . . . . . . .

Pagina 8 - Safety (EEC)

TABLE OF CONTENTSxiiMounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-4Rack Mounting . .

Pagina 9 - Power Cord Safety

TABLE OF CONTENTSxiiiAPPENDICES:A Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .A-1Diagnosing Switch Indicators . . .

Pagina 10 - OMPLIANCES

TABLE OF CONTENTSxivGlossaryIndex

Pagina 11

xvTABLESTable 1-1 Port Status LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-5Table 1-2 System Status LEDs . . . . . .

Pagina 13 - Environmental Statement

xviFIGURESFigure 1-1 Front Panels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2Figure 1-2 Rear Panel . . . . . . . . .

Pagina 14 - Related Publications

1-1CHAPTER 1ABOUT THETIGERSTACK II 10/100/1000OverviewSMC’s TigerStack II 10/100/1000 SMC8824M and SMC8848M are intelligent multilayer switches (Layer

Pagina 15

ABOUT THE TIGERSTACK II 10/100/10001-2These switches can be used to augment or completely replace slow legacy routers, off-loading local IP traffic to

Pagina 16

DESCRIPTION OF HARDWARE1-3These switches include built-in stacking ports that enable up to eight units to be connected together through a 48 Gbps stac

Pagina 17 - APPENDICES:

ABOUT THE TIGERSTACK II 10/100/10001-4SFP SlotsThe Small Form Factor Pluggable (SFP) transceiver slots are shared with four of the RJ-45 ports (ports

Pagina 18

DESCRIPTION OF HARDWARE1-5Port and System Status LEDsThese switches include a display panel for key system and port indications that simplify installa

Pagina 19

ABOUT THE TIGERSTACK II 10/100/10001-6Figure 1-4 System LEDsTable 1-2 System Status LEDsLED Condition StatusPower Green Internal power is operating

Pagina 20

DESCRIPTION OF HARDWARE1-7Stack MasterGreen Switch is the Master unit of the stack. State may include topology discovery, IP assignment, or normal ope

Pagina 21 - Overview

ABOUT THE TIGERSTACK II 10/100/10001-8Optional Redundant Power SupplySMC supports an optional Redundant Power Supply (RPS), that can supply power to t

Pagina 22 - SMC8824M

FEATURES AND BENEFITS1-9Extender Module LEDsThe optional 10GBASE slide-in module includes its own integrated LED indicators on the module’s front pane

Pagina 23 - Description of Hardware

38 TeslaIrvine, CA 92618Phone: (949) 679-8000TigerStack II 10/100/1000Installation GuideFrom SMC’s Tiger line of feature-rich workgroup LAN solutionsF

Pagina 24

ABOUT THE TIGERSTACK II 10/100/10001-10• Provides stacking capability via high-speed serial ports with 48 Gbps stacking bandwidth. Up to 8 units can b

Pagina 25 - Port and System Status LEDs

2-1CHAPTER 2NETWORK PLANNINGIntroduction to SwitchingA network switch allows simultaneous transmission of multiple packets via non-crossbar switching.

Pagina 26 - Figure 1-4 System LEDs

NETWORK PLANNING2-2Application ExamplesThe TigerStack II 10/100/1000 is not only designed to segment your network, but also to provide a wide range of

Pagina 27 - ESCRIPTION

APPLICATION EXAMPLES2-3Network Aggregation PlanWith 24 or 48 parallel bridging ports (i.e., 24 or 48 distinct collision domains), a Gigabit switch sta

Pagina 28 - Redundant Power Socket

NETWORK PLANNING2-4Remote Connections with Fiber CableFiber optic technology allows for longer cabling than any other media type. A 1000BASE-SX (MMF)

Pagina 29 - Features and Benefits

APPLICATION EXAMPLES2-5Making VLAN ConnectionsThese switches support VLANs which can be used to organize any group of network nodes into separate broa

Pagina 30

NETWORK PLANNING2-6Application Notes1. Full-duplex operation only applies to point-to-point access (such as when a switch is attached to a workstation

Pagina 31 - Introduction to Switching

3-1CHAPTER 3INSTALLING THE SWITCHSelecting a SiteTigerStack II 10/100/1000 units can be mounted in a standard 19-inch equipment rack or on a flat surf

Pagina 32 - Application Examples

INSTALLING THE SWITCH3-2Ethernet CablingTo ensure proper operation when installing the switches into a network, make sure that the current cables are

Pagina 33 - Network Aggregation Plan

EQUIPMENT CHECKLIST3-3Equipment ChecklistAfter unpacking the TigerStack II 10/100/1000 unit, check the contents to be sure you have received all the c

Pagina 34 - (5 kilometers)

Information furnished by SMC Networks, Inc. (SMC) is believed to be accurate and reliable. However, no responsibility is assumed by SMC for its use, n

Pagina 35 - Making VLAN Connections

INSTALLING THE SWITCH3-4MountingA TigerStack II 10/100/1000 unit can be mounted in a standard 19-inch equipment rack or on a desktop or shelf. Mountin

Pagina 36 - Application Notes

MOUNTING3-5To rack-mount devices:1. Attach the brackets to the device using the screws provided in the Bracket Mounting Kit.Figure 3-2 Attaching the

Pagina 37 - Selecting a Site

INSTALLING THE SWITCH3-63. If installing a single switch only, turn to “Connecting to a Power Source” at the end of this chapter.4. If installing mult

Pagina 38 - Ethernet Cabling

INSTALLING AN OPTIONAL MODULE INTO THE SWITCH3-7Installing an Optional Module into the SwitchFigure 3-5 Installing an Optional ModuleNote: The slide-

Pagina 39 - Equipment Checklist

INSTALLING THE SWITCH3-86. The Module LED on the switch’s front panel should turn green to confirm that the module is correctly installed and ready to

Pagina 40 - Mounting

CONNECTING SWITCHES IN A STACK3-93. Slide the transceiver into the slot until it clicks into place.Note: SFP and XFP transceivers are hot-swappable. T

Pagina 41 - TigerStackII

INSTALLING THE SWITCH3-104. (Optional) To form a wrap-around topology, plug one end of a stack cable into the Down port on the bottom unit and the oth

Pagina 42 - NSTALLING

CONNECTING SWITCHES IN A STACK3-11Stacking TopologiesAll units in the stack must be connected via stacking cable. You can connect units in a simple ca

Pagina 43

INSTALLING THE SWITCH3-12Connecting to a Power SourceTo connect a device to a power source:1. Insert the power cable plug directly into the socket loc

Pagina 44 - Installing an Optional

CONNECTING TO THE CONSOLE PORT3-13Connecting to the Console Port The RJ-45 serial port on the switch’s front panel is used to connect to the switch fo

Pagina 45 - ONNECTING

iLIMITED WARRANTYLimited Warranty Statement: SMC Networks, Inc. (“SMC”) warrants its products to be free from defects in workmanship and materials, un

Pagina 46

INSTALLING THE SWITCH3-14

Pagina 47

4-1CHAPTER 4MAKING NETWORKCONNECTIONSConnecting Network DevicesThe TigerStack II 10/100/1000 units are designed to interconnect multiple segments (or

Pagina 48 - Connecting to a Power Source

MAKING NETWORK CONNECTIONS4-2Connecting to PCs, Servers, Hubs and Switches1. Attach one end of a twisted-pair cable segment to the device’s RJ-45 conn

Pagina 49

TWISTED-PAIR DEVICES4-3Network Wiring ConnectionsToday, the punch-down block is an integral part of many of the newer equipment racks. It is actually

Pagina 50

MAKING NETWORK CONNECTIONS4-4Fiber Optic SFP DevicesAn optional Gigabit SFP transceiver (1000BASE-SX, 1000BASE-LX or 1000BASE-ZX) can be used for a ba

Pagina 51 - Twisted-Pair Devices

10 GBPS FIBER OPTIC CONNECTIONS4-53. Connect one end of the cable to the LC port on the switch and the other end to the LC port on the other device. S

Pagina 52 - ONNECTIONS

MAKING NETWORK CONNECTIONS4-6Warning: These switches use lasers to transmit signals over fiber optic cable. The lasers are compliant with the requirem

Pagina 53

10 GBPS FIBER OPTIC CONNECTIONS4-7Figure 4-4 Connecting to an XFP Transceiver4. As a connection is made, check the Link LED on the module to be sure

Pagina 54 - Fiber Optic SFP Devices

MAKING NETWORK CONNECTIONS4-8Connectivity RulesWhen adding hubs (repeaters) to your network, please follow the connectivity rules listed in the manual

Pagina 55

CONNECTIVITY RULES4-91000 Mbps Gigabit Ethernet Collision DomainTable 4-2 Maximum 10GBASE-LR 10 Gigabit Ethernet Cable LengthFiber Size Fiber Bandwid

Pagina 56

iiWARRANTIES EXCLUSIVE: IF AN SMC PRODUCT DOES NOT OPERATE AS WARRANTED ABOVE, CUSTOMER’S SOLE REMEDY SHALL BE REPAIR OR REPLACEMENT OF THE PRODUCT IN

Pagina 57

MAKING NETWORK CONNECTIONS4-10100 Mbps Fast Ethernet Collision Domain10 Mbps Ethernet Collision DomainTable 4-7 Maximum 1000BASE-ZX Fiber Optic Cable

Pagina 58 - Connectivity Rules

CABLE LABELING AND CONNECTION RECORDS4-11Cable Labeling and Connection RecordsWhen planning a network installation, it is essential to label the oppos

Pagina 59 - ONNECTIVITY

MAKING NETWORK CONNECTIONS4-12

Pagina 60

A-1APPENDIX ATROUBLESHOOTINGDiagnosing Switch Indicators Table A-1 Troubleshooting ChartSymptom ActionPower LED is Off • Check connections between th

Pagina 61 - ONNECTION

TROUBLESHOOTINGA-2Diagnosing Power Problems with the LEDsThe Power and RPS LEDs work in combination to indicate power status as follows.Stack Link LED

Pagina 62

POWER AND COOLING PROBLEMSA-3Power and Cooling ProblemsIf the power indicator does not turn on when the power cord is plugged in, you may have a probl

Pagina 63 - ROUBLESHOOTING

TROUBLESHOOTINGA-4Stack TroubleshootingIf a stack fails to initialize or function, first check the following items:• Check that all stacking cables ar

Pagina 64 - Table A-2 Power/RPS LEDs

B-1APPENDIX BCABLESTwisted-Pair Cable and Pin AssignmentsFor 10BASE-T/100BASE-TX connections, a twisted-pair cable must have two pairs of wires. For 1

Pagina 65 - In-Band Access

CABLESB-210BASE-T/100BASE-TX Pin AssignmentsUse unshielded twisted-pair (UTP) or shielded twisted-pair (STP) cable for RJ-45 connections: 100-ohm Cate

Pagina 66 - Stack Troubleshooting

TWISTED-PAIR CABLE AND PIN ASSIGNMENTSB-3Straight-Through WiringIf the twisted-pair cable is to join two ports and only one of the ports has an intern

Pagina 67

iiiCOMPLIANCESFCC - Class AThis equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the

Pagina 68

CABLESB-4Crossover WiringIf the twisted-pair cable is to join two ports and either both ports are labeled with an “X” (indicating MDI-X) or neither po

Pagina 69

TWISTED-PAIR CABLE AND PIN ASSIGNMENTSB-51000BASE-T Pin Assignments All 1000BASE-T ports support automatic MDI/MDI-X operation, so you can use straigh

Pagina 70 - Crossover Wiring

CABLESB-6Note that when testing your cable installation, be sure to include all patch cables between switches and end devices.Adjusting Existing Categ

Pagina 71

C-1APPENDIX CSPECIFICATIONSPhysical CharacteristicsPortsSMC8824M20 10/100/1000BASE-T, with auto-negotiation4 10/100/1000BASE-T shared with 4 SFP trans

Pagina 72 - Fiber Standards

SPECIFICATIONSC-2Switching Database8K MAC address entries, 1K static MAC addresses;2K IP or 1K IPv6 entries in host table, 1K ARP entries,512 IP or 25

Pagina 73 - SPECIFICATIONS

SWITCH FEATURESC-3Maximum CurrentSMC8824M: 0.59 A @ 110 VAC (without expansion modules)0.72 A @ 110 VAC (with two expansion modules)0.36 A @ 240 VAC

Pagina 74 - PECIFICATIONS

SPECIFICATIONSC-4StandardsIEEE 802.3-2002 Ethernet, Fast Ethernet, Gigabit EthernetIEEE 802.3ae 10 Gigabit EthernetIEEE 802.1D Spanning Tree ProtocolI

Pagina 75 - Management Features

EXTENDER MODULESC-5Extender Modules10G Extender Module (XFP)Ports1 slot for 10GBASE XFP transceiver Communication Speed10 GbpsCommunication ModeFull d

Pagina 76 - Compliances

SPECIFICATIONSC-6

Pagina 77 - Warranty

D-1APPENDIX DGERMAN INSTRUCTIONSEine Site Auswählen (Selecting a Site - German)Die Schalter können in ein Standard-19-Zoll-Ausrüstungsgestell oder auf

Pagina 78

COMPLIANCESivCE Mark Declaration of Conformance for EMI and Safety (EEC)SMC contact for these products in Europe is:SMC Networks Europe,Edificio Conat

Pagina 79 - GERMAN INSTRUCTIONS

MONTAGE (RACK MOUNTING INSTRUCTIONS - GERMAN)D-2moglichen elektrischen Storungen verlegt wird, wie z. B. von Radios und Transmittern.• Sicherstellen,

Pagina 80 - NSTRUCTIONS

GERMAN INSTRUCTIONSD-3So montieren Sie Geräte an ein Rack:1. Befestigen Sie die Metallwinkel mit den im Metallwinkel-Montageset erhältlichen Schrauben

Pagina 81

MONTAGE (RACK MOUNTING INSTRUCTIONS - GERMAN)D-4

Pagina 82

E-1APPENDIX EORDERING INFORMATIONTable E-1 TigerStack II 10/100/1000 Products and AccessoriesProduct Number DescriptionSMC8848M 48-port 10/100/1000 s

Pagina 83 - NFORMATION

ORDERING INFORMATIONE-2

Pagina 84

Glossary-1GLOSSARY10BASE-TIEEE 802.3 specification for 10 Mbps Ethernet over two pairs of Category 3 or better UTP cable.100BASE-TXIEEE 802.3u specifi

Pagina 85 - GLOSSARY

GLOSSARYGlossary-210GBASE-LRIEEE 802.3ae specification for 10 Gigabit Ethernet over two strands of 9/125 micron core single-mode fiber cable.10GBASE-S

Pagina 86 - Glossary-2

GLOSSARYGlossary-3End StationA workstation, server, or other device that does not forward traffic.EthernetA network communication system developed and

Pagina 87 - Glossary-3

GLOSSARYGlossary-4IEEE 802.3aeDefines the physical layer specifications for 10 Gigabit Ethernet.IEEE 802.3uDefines CSMA/CD access method and physical

Pagina 88 - Glossary-4

GLOSSARYGlossary-5Management Information Base (MIB)An acronym for Management Information Base. It is a set of database objects that contains informati

Pagina 89 - Glossary-5

COMPLIANCESvAustralia AS/NZS 3548 (1995) - Class ASMC contact for products in Australia is:SMC Communications Pty. Ltd.Suite 18, 12 Tryon Road, Lindfi

Pagina 90 - Glossary-6

GLOSSARYGlossary-6Transmission Control Protocol/Internet Protocol (TCP/IP)Protocol suite that includes TCP as the primary transport protocol, and IP a

Pagina 91 - , 4-9, 4-10

Index-1Numerics10 Gbps connectivity rules 4-810 Mbps connectivity rules 4-10100 Mbps connectivity rules 4-101000 Mbps connectivity rules 4-91000BASE-L

Pagina 92

INDEXIndex-2Ggrounding for racks 3-4IIEEE 802.3 Ethernet 1-9IEEE 802.3ae 10 Gigabit Ethernet 1-9IEEE 802.3u Fast Ethernet 1-9IEEE 802.3z Gigabit Ether

Pagina 93

INDEXIndex-3Rrack mounting 3-4redundant power unit 1-8RJ-45 port 1-3connections 4-1pinouts B-5RPUconnecting 3-12installing in a rack 3-6installing on

Pagina 94

INDEXIndex-4

Pagina 96

38 TeslaIrvine, CA 92618Phone: (949) 679-8000Model Numbers: SMC8824M, SMC8848MPub. Number: 150200054300A E022006-R01FOR TECHNICAL SUPPORT, CALL:From U