3-4
Mounting
A TigerStack 1000 unit can be mounted in a standard 19-inch equipment
rack or on a desktop or shelf. Mounting instructions for each type of site
follow.
Rack Mounting
Before rack mounting the switch, pay particular attention to the following
factors:
Temperature: Since the temperature within a rack assembly may be
higher than the ambient room temperature, check that the
rack-environment temperature is within the specified operating
temperature range (see page C-2).
Mechanical Loading: Do not place any equipment on top of a
rack-mounted unit.
Circuit Overloading: Be sure that the supply circuit to the rack assembly
is not overloaded.
Grounding: Rack-mounted equipment should be properly grounded.
Particular attention should be given to supply connections other than
direct connections to the mains.